Threaded Pipe Flange: Types, Standards, Sizes, and Selection Guide

24, Nov. 2026

 

Threaded Pipe Flange: Types, Standards, Sizes, and Selection Guide

A threaded pipe flange, also called a screwed flange, connects to a pipe through matching internal and external threads rather than a welded joint. It can be considered when welding is impractical or undesirable, but the flange thread, pipe thread, material, pressure class, and service conditions must all be compatible. ASME B16.5 covers flange sizes from NPS 1/2 to NPS 24, although the available pressure class depends on the size and flange configuration. This guide explains the main types, standards, size references, and purchasing checks buyers can use to define a suitable specification.

For more information, please visit our website.

Who This Guide Is For

This guide is for project engineers, procurement teams, maintenance buyers, and distributors sourcing threaded flanges for stainless steel piping systems. It is useful when preparing a request for quotation, reviewing a supplier proposal, or checking whether a threaded connection fits an existing line. The final selection should be verified against the project’s piping code, design documents, and applicable standard. Where requirements are unclear, confirm them with the responsible engineer before ordering.

How Threaded Pipe Flanges Work

Basic construction and purpose

A threaded flange has a central bore with an internal thread intended to engage a pipe with a matching external thread. Once assembled, the flange can be bolted to another compatible flange using a gasket where the joint design calls for one. The threaded pipe connection and the bolted flange face are separate interfaces, so both need to be specified and checked. A correctly selected flange helps provide a detachable connection point for equipment, valves, or another section of piping.

Because installation does not require welding the flange to the pipe, threaded flanges may be useful where welding access, hot-work controls, or field conditions make a welded connection difficult. However, avoiding welding does not automatically make a threaded joint suitable for every service. Threaded joints can be sensitive to assembly quality, vibration, thermal cycling, and the nature of the fluid. Evaluate those factors as part of the piping design rather than selecting by convenience alone.

Types, Materials, and Standards

Common flange forms and facing

Threaded flanges are commonly supplied with a raised face or a flat face, depending on the applicable standard and mating equipment. The facing affects gasket selection and how the bolted joint is assembled. Some specifications also identify a ring-type joint facing, but availability and suitability must be confirmed for the flange size, class, and standard. Do not assume that two flanges are interchangeable simply because their bolt holes appear similar.

Materials for stainless steel piping

Stainless steel threaded flanges may be specified in grades such as 304/304L or 316/316L, subject to the design requirements and available product standard. The grade should be matched to the fluid, temperature, corrosion exposure, and connected pipe material. A stainless steel flange does not by itself establish corrosion resistance for the complete assembly: the pipe, gasket, fasteners, and thread sealant may also affect performance. Ask the supplier to identify the material grade and the documentation available for the supplied product.

Standards and thread compatibility

ASME B16.5 is a widely used standard for pipe flanges and flanged fittings, covering NPS 1/2 through NPS 24. It defines dimensional and rating requirements within its scope, but not every size-and-class combination is available for every flange type. Other projects may specify a different national or international flange standard, so the purchase specification should name the required standard and edition where applicable. A flange made to one dimensional system should not be presumed compatible with another.

Thread form is another critical specification. Common pipe-thread systems include NPT, which is tapered, and BSP thread families, which include parallel and tapered forms. These thread systems are not automatically interchangeable; matching nominal size alone does not ensure proper engagement or sealing. State the required thread designation explicitly and verify it against the pipe end and project standard.

You will get efficient and thoughtful service from Longrun.

Size and Specification Overview

Nominal pipe size is a designation, not a direct measurement of the flange’s outside diameter or bore. For example, NPS 2 is commonly associated with DN 50, but the flange’s outside diameter, bolt circle, thickness, and facing dimensions depend on the selected standard and pressure class. Use the applicable standard’s dimensional table or approved drawing to confirm dimensions before fabrication or installation. The examples below are nominal size references, not a dimensional interchangeability table.

Nominal pipe size Approximate DN reference Buyer verification
NPS 1/2 DN 15 Confirm flange standard, class, and thread form
NPS 1 DN 25 Confirm bore and mating flange dimensions
NPS 2 DN 50 Check thread engagement and pressure rating
NPS 4 DN 100 Verify the size-and-class combination in the selected standard

Pressure class is not a universal operating pressure stated in psi for every service condition. A flange rating depends on factors such as material and temperature, as defined by the governing standard. ASME B16.5 includes pressure classes such as Class 150, 300, 600, 900, 1500, and 2500, but a particular class may not be offered for every size or flange configuration. Confirm the rating using the standard and the project’s design conditions, rather than treating the class number as a direct pressure value.

How to Select a Threaded Pipe Flange

Use a practical specification checklist

  1. Define the service. Record the fluid, design pressure, design temperature, and relevant corrosion or cleanliness requirements.
  2. Identify the piping standard. Specify the flange standard, edition if required, nominal size, and pressure class.
  3. Match the thread. State the exact thread designation and confirm that the pipe end uses the same compatible form and size.
  4. Select material and facing. Confirm flange grade, mating-face type, gasket requirements, and compatibility with the connected components.
  5. Check installation conditions. Consider access, assembly procedure, vibration, thermal cycling, and whether the joint will need periodic disassembly.
  6. Verify documents and dimensions. Request a drawing or dimensional confirmation and specify any required material or inspection records.

Threaded flanges are often considered for smaller-bore lines or locations where welding is restricted, but application suitability must be confirmed for each project. They may be a poor choice where frequent vibration, severe thermal cycling, or a particularly demanding leak-control requirement makes a threaded connection difficult to maintain. In those cases, the engineering team may compare welded or other connection designs. Selection should follow the governing code and the system designer’s approval.

Pricing, MOQ, and Lead-Time Considerations

Quoted price can vary with size, pressure class, material grade, thread type, facing, standard, quantity, and documentation needs. Custom machining or a less commonly stocked combination may affect production planning, while consolidated quantities can change the commercial offer. Minimum order quantity and lead time are supplier-specific and should be confirmed for the exact specification rather than assumed from a general catalogue. For time-sensitive projects, include required delivery dates and approval steps in the inquiry.

Supplier Evaluation Checklist

  • Can the supplier confirm the flange standard, size, class, material, facing, and thread designation in writing?
  • Can they provide a dimensional drawing or product details for review before order confirmation?
  • Are material identification and inspection documents available if the project requires them?
  • Do the quotation, packaging, and delivery terms match the project’s quantity and schedule?
  • Can the supplier clarify which requirements are standard and which require special production or documentation?

Longrun supplies stainless steel piping products and can help buyers review the information needed for a threaded flange inquiry. Share the required standard, nominal size, pressure class, material grade, thread form, facing, quantity, and delivery location so the specification can be assessed clearly. Availability, documentation, MOQ, and lead time should be confirmed against the specific order.

Key Takeaways and Next Steps

A threaded pipe flange joins to a pipe through matching threads and bolts to a mating flange, making it a potential option where welding is not preferred or practical. The correct choice depends on more than nominal size: buyers must align the flange standard, class, material, facing, thread form, and service conditions. Use standard dimensional data to verify the assembly, and do not assume NPT and BSP threads or different flange systems are interchangeable.

To move forward, prepare a complete specification and have the responsible engineer confirm suitability for the application. Then request a supplier quotation that identifies the product details, available documentation, MOQ, and delivery timing. Longrun can review your stainless steel flange requirements and discuss the appropriate supply options for your project.

If you are looking for more details, kindly visit Threaded Pipe Flange.